1) 100 % rated value acc. to UL 489 and IEC 60947-2
(100 % rated breaker).
2) Circuit breakers for system protection of motor and
non-motor loads. Requires use of separate overload
protection for motor applications.
3) Circuit breakers for system and transformer protection
according to UL/CSA. Specially designed for trans-
formers with high inrush current.
4) Transverse and lateral auxiliary switches can be
ordered separately (see “Mountable accessories”).
5) Transverse auxiliary switches must not be mounted.
Lateral auxiliary switches can be ordered separately
(see “Mountable accessories”).
Selection and ordering data
For Motor
Protection
2)
For Transformer
Protection
3)
Rated
Cur-
rent
1)
[A]
Thermal
overload
release
(non-ad-
justable)
[A]
Short Circuit
breaking capacity
[kA]
Instant-
aneous
Over
Current
Release
[A]
Order
Number
(Screw
Terminals)
Weight
[kg]
Instant-
aneous
Over
Current
Release
[A]
Order
Number
(Screw
Terminals)
Weight
[kg]
480
VAC
480Y/
277VAC
600Y/
347VAC
Innovations Frame Size S00
4)
0.16 0.16 65 10 2.1
3RV2711-0AD10
0.390 3.3
3RV2811-0AD10
0.390
0.2 0.2 65 10 2.6
3RV2711-0BD10
0.390 4.2
3RV2811-0BD10
0.390
0.25 0.25 65 10 3.3
3RV2711-0CD10
0.390 5.2
3RV2811-0CD10
0.390
0.32 0.32 65 10 4.2
3RV2711-0DD10
0.390 6.5
3RV2811-0DD10
0.390
0.4 0.4 65 10 5.2
3RV2711-0ED10
0.390 8.2
3RV2811-0ED10
0.390
0.5 0.5 65 10 6.5
3RV2711-0FD10
0.390 10
3RV2811-0FD10
0.390
0.63 0.63 65 10 8.2
3RV2711-0GD10
0.390 13
3RV2811-0GD10
0.400
0.8 0.8 65 10 10
3RV2711-0HD10
0.390 16
3RV2811-0HD10
0.450
1 1 65 10 13
3RV2711-0JD10
0.450 21
3RV2811-0JD10
0.450
1.25 1.25 65 10 16
3RV2711-0KD10
0.450 26
3RV2811-0KD10
0.460
1.6 1.6 65 10 21
3RV2711-1AD10
0.460 33
3RV2811-1AD10
0.460
2 2 65 10 26
3RV2711-1BD10
0.460 42
3RV2811-1BD10
0.460
2.5 2.5 65 10 33
3RV2711-1CD10
0.460 52
3RV2811-1CD10
0.460
3.2 3.2 65 10 42
3RV2711-1DD10
0.460 65
3RV2811-1DD10
0.460
4 4 65 10 52
3RV2711-1ED10
0.450 82
3RV2811-1ED10
0.460
5 5 65 10 65
3RV2711-1FD10
0.460 104
3RV2811-1FD10
0.460
6.3 6.3 65 10 82
3RV2711-1GD10
0.460 130
3RV2811-1GD10
0.460
8 8 65 10 104
3RV2711-1HD10
0.460 163
3RV2811-1HD10
0.460
10 10 65 10 130
3RV2711-1JD10
0.460 208
3RV2811-1JD10
0.460
12.5 12.5 65 10 163
3RV2711-1KD10
0.460 260
3RV2811-1KD10
0.460
15 15 65 208
3RV2711-4AD10
0.470 286
3RV2811-4AD10
0.470
Innovations Frame Size S0
4)
20 20 50 260
3RV2721-4BD10
0.514 325
3RV2821-4BD10
0.516
22 22 50 286
3RV2721-4CD10
0.516 364
3RV2821-4CD10
0.528
Innovations Frame Size S3
5)
10 10 65 20 150
3RV2742-5AD10
0.460
15 15 65 20 225
3RV2742-5BD10
0.460
20 20 65 20 260
3RV2742-5CD10
0.460
25 25 65 20 325
3RV2742-5DD10
0.460
30 30 65 20 390
3RV2742-5ED10
0.460
35 35 65 20 455
3RV2742-5FD10
0.460
40 40 65 20 520
3RV2742-5GD10
0.460
45 45 65 20 585
3RV2742-5HD10
0.460
50 50 65 20 650
3RV2742-5JD10
0.460
60 60 65 20 780
3RV2742-5LD10
0.460
70 70 65 10 910
3RV2742-5QD10
0.460
Refer to page 1/21 when using as upstream protection of a Manual Motor Controller or a Manual Motor Controller Suitable for Tap Conductor Protection in
Group Installations.
Product Category IEC
3RV Circuit Breakers
UL 489
3RV
up to 70 A