Install Instructions

Instructions
October, 1999
Supersedes Issue of
June, 1996
Siemens Energy & Automation, Inc. 1000 McKee Street Batavia, Illinois 60510
75-HES2
Replacement Contact Cartridge
Class 69
Cat. No. 75ES1 & 75ES2
File LR6535
File E14861
DESCRIPTION
Furnas Pro Control replacement contact cartridges are for use
with 69ES Pro Control pressure switches.The cartridges are fac-
tory set per the table below.
Pressure Replacement Factory
Switch Cartridge Differential
Cat No Cat No Max Hp Settings
69ES1 75ES1 3 20 psi +/-3 psi
69ES2 75ES2 5 20 psi +/-3 psi
CONTENTS OF KIT:
(1) Replacement contact cartridge
(2) Captive mounting screws
INSTALLATION
WARNING!
To avoid electric shock, turn off electrical power to the con-
trols before performing installation or maintenance.
ADERTISSEMENT!
Avant installation ou entretien couper les circuits de com-
mande pour eviter tout choc electrique.
1. Loosen the captive cover screw (A) and remove
pressure switch cover.
2. Tag and remove line and load terminal wires.
3. Loosen the mounting screws (B) on each side of the
contact cartridge so that they are free of the frame.
Remove the cartridge by lifting upward.
4. To mount the new contact cartridge, line up as shown
in Fig. 1. The nibs on the contact cartridge, insert
and engage into the cutout on the pressure switch
housing.
5. Tighten mounting screws. Reconnect wires and
replace switch cover.
6. Reconnect power.
NOTE:
The pressure differential of these cartridges are factory set per
the table above. After changing a cartridge, minor adjustments
may be required. If necessary, adjust per gauge on pressure
tank.
(For Engineering Reference Only - Rev. E)