Installation Manual

3. SETTING AND ADJUSTMENT
3-9
10. Select [ON] to enable AIS data output to the NAVNET network when this unit is
turned on. Select [OFF] to disable AIS data output when this unit is turned on.
11. Set [ZDA INFO] and [GPS INFO] in the same manner as [AIS INFO], then go to
step 14.
12. Select [SFI], then press the ENT/ACK key.
13. Set the [SFI] (System Function ID), then press the ENT/ACK key.
14. Confirm the settings are correct, then select [<SAVE>] and press the ENT/ACK
key. A confirmation pop up is displayed.
Note: If no changes are made to the settings, [<SAVE>] is not selectable.
15. Select [NO] to change the settings further. Select [YES] to accept the new set-
tings, the unit now shuts down automatically to apply the new settings. When the
unit is shut down, press the power key to restart the unit.
3.7 SERVICE Menu Operations
The [SERVICE] menu is password protected. Contact FURUNO for password details.
The following items require access to the SERVICE for initial
setup:
ALERT MODE settings
• Network protocol settings
Restore Factory settings
3.7.1 How to access the SERVICE menu
1. From the [MAIN] menu, select [SERVICE], then press the ENT/ACK key. The
password input pop up appears.
2. Input the password then press the ENT/ACK key.
3.7.2 How to set the alert mode
The alert mode can be set according to the vessel’s configuration. The available alert
modes are: [LEGACY ED.1], [LEGACY ED.2], [ALERT IF1] and [ALERT IF2].
1. Access the [SERVICE] menu referring to the procedure outlined at the start of this
section.
2. Select [ALERT SET], then press the ENT/ACK key.
3. Select [ALERT MODE], then press the ENT/ACK key.
Note: The [OPERATIONAL] setting is
for technical personnel only. Do not
change this setting.
4. Select the appropriate [ALERT MODE]
setting, then press the ENT/ACK key.
Select [ALERT IF1] for vessels configured with AMS, [ALERT IF2] for vessels con-
figured with BAM.
5. Press the MENU/ESC key to return to the [INTIAL SET] menu, or press the DISP
key to close all open menus.
SERVICE
CH SET
AIS SET
ALERT SET
FACTORY SET
OTHER SET
INITIALIZE
1
2
3
4
5
6
TEST
7
MAINTENANCE
8
DEVELOPER
9
ALERT SET
ALERT MODE LEGACY ED.2
OPERATIONAL
1
2
LEGACY ED.1
LEGACY ED.2
ALERT IF1
ALERT IF2