User's Manual

4. INSTALLATION
4-2
Flush mounting
The display unit can be installed flush mounted in a console or panel by using
the optional flush mount kit.
.
(For NX-700A)
Type: OP08-19 Code No.: 004-514-810
Name Type Code No. Qty Remarks
Mounting metal 08-023-1019 100-326-960 1
Self-tapping screw 5X20 000-802-081 6
Hex. bolt M8x15 000-862-144 2
Spring washer M8 000-864-262 2
1. Cut out a hole with dimensions as shown below in the mounting location.
7
275+1
156+1
284+0.5
30+1
168+0.5
7
5
2. Attach the fixing metal to the display unit with two hex. bolts (M8x15,
supplied with optional kit) and spring washers (supplied with optional kit).
3. Fasten six self-tapping screws to fix the display unit to the mounting location.
(For NX-700B)
Type: OP08-20 Code No.: 004-514-820
Name Type Code No. Qty Remarks
Mounting metal 08-023-2011 100-327-010 1
Self-tapping screw 5x20 000-802-081 4
Pan head screw M4x12 000-802-130 4
1. Cut out a hole with dimensions as shown below in the mounting location.
156+1
155+0.5
144+1
155+0.5
5
2. Attach the fixing metal to the display unit with four pan head screws (M4X12,
supplied with the optional kit).
3. Fasten four self-tapping screws (supplied with the optional kit) to fix the
display unit to the mounting location.