User Manual

FURUNO
FAR-21x7(-BB)/28x7 SERIES
SP - 4 E3519S01L-P
8. PERFORMANCE MONITOR
PM-31 (X-band)
1. Frequency range 9370 to 9450 MHz
2. Input power Min.: +8 dBm, Max.: +28 dBm
3. Power output (2
nd
pulse max output) -36 dBm
4. Power output (2
nd
pulse min output) -56 dBm
5. Step levels (1
st
pulse to 2
nd
pulse) 7.5 to 10.5 dB
PM-51 (S-band)
1. Frequency range 3020 to 3080 MHz
2. Input power Min.: -5 dBm, Max.: +15 dBm
3. Power output (2
nd
pulse max output) -15 dBm
4. Power output (2
nd
pulse min output) -35 dBm
5. Step levels (1
st
pulse to 2
nd
pulse) 9.0 to 11.0 dB
9. SWITCHING HUB HUB-100
1. Access Format CSMA/CD
2. Switching Format Store and Forward
3. Transmission Speed Half-duplex: 10 Mbps/100 Mbps
Full-duplex: 20 Mbps/200 Mbps
4. Necessary Cabling 10BASE-T: Category 3 or higher STP cable
100 BASE-TX: Category 5 or higher STP cable
5. Max. Cable Length 100 m
6. Ports 8 ports
- All ports auto-MDIX compliant (straight or cross cable,
automatic recognition)
- All ports EMC compliant (STP cable port)
- All ports equipped with 3 LED injectors
(Link/Act, Full-duplex/Collision, 100 Mbps/10 Mbps)
7. Buffer Memory SRAM buffer
8. MAC Address Table 1024
9. Environmental Conditions
Ambient Temperature -15 to +50°C
Relative Humidity 95% (at 40°C)
EMC IEC 60945
Waterproofing IPX0
10. Power and Power Consumption
Power 100-230 VAC
Power Consumption 100mA/100 VAC
11. Coating and Color N3.0