User Manual Part 2

4. AIS OPERATION
4-5
4.8 How to Display the Targets within a Specific Sec-
tor
You can display AIS targets only within a specific sector. If the target sorting method
is selected to [Sector], the target data within the sector set here is transmitted to this
radar.
1. Press the MENU key to open the menu.
2. Use the Cursorpad (S or T) to select [AIS] and press the ENTER key.
3. Use the Cursorpad (S or T) to select [Sector Start] and press the ENTER key.
Sector Start setting window
4. Use the Cursorpad (S or T) to set the start point for the sector and press the EN-
TER key.
5. Use the Cursorpad (S or T) to select [Sector End] and press the ENTER key.
Sector End setting window
6. Use the Cursorpad (S or T) to set the end point for the sector and press the EN-
TER key.
7. Press the MENU key to close the menu.
4.9 Number of Targets to Display
You can select the maximum number of AIS targets to display. The setting value is 10
to 100. When the screen becomes cluttered with AIS targets, you can limit the number
of AIS targets to show. Targets are selected and displayed according to sort method.
(See section 4.6.)
1. Press the MENU key to open the menu.
2. Use the Cursorpad (S or T) to select [AIS] and press the ENTER key.
3. Use the Cursorpad (S or T) to select [Number of Targets] and press the ENTER
key.
Number of Targets setting window