Installation Manual RADAR SENSOR DRS2D/DRS4D/ DRS4A/DRS6A/DRS12A/DRS25A SAFETY INSTRUCTIONS ............................................................................ i SYSTEM CONFIGURATION ....................................................................... ii EQUIPMENT LISTS.................................................................................... iv 1. MOUNTING ............................................................................................ 1 1.1 1.2 1.3 1.
SAFETY INSTRUCTIONS WARNING WARNING Do not open the equipment unless totally familiar with electrical circuits and service manual. Radio Frequency Radiation Hazard The radar antenna emits electromagnetic radio frequency (RF) energy which can be harmful, particularly to your eyes. Never look directly into the antenna aperture from a close distance while the radar is in operation or expose yourself to the transmitting antenna at a close distance. Only qualified personnel should work inside the equipment.
SYSTEM CONFIGURATION DRS2D/4D/4A/6A/12A RADAR SENSOR DRS2D/DRS4D RADAR SENSOR DRS4A/DRS6A/DRS12A NMEA 2000 Equipment NMEA 2000 Equipment Power Supply Unit PSU-012* 12-24 VDC OR Multi Function Display BlackBox MFDBB Multi Function Display MFD8/12 : Standard Supply : Optional Supply RECTIFIER RU-1746B 12-24 VDC : Local Supply 100/110/220/230 VAC *The power supply unit PSU-012 is necessary in the combination of radar sensor and MFD.
DRS25A RADAR SENSOR DRS25A NMEA 2000 Equipment Power Supply Unit PSU-013 12-24 VDC Multi Function Display BlackBox MFDBB OR Multi Function Display MFD8/12 RECTIFIER RU-1746B : Standard Supply : Optional Supply : Local Supply 12-24 VDC iii 100/110/220/230 VAC
EQUIPMENT LISTS Standard supply Name Radar Sensor Type XN10A-RSB-118-092 Code No.
Optional supply Name Type Code No.
1. MOUNTING 1.1 Mounting Considerations • The radar sensor is generally installed either on top of the wheelhouse or on the radar mast on a suitable platform. Locate the radar sensor where there is a good all-round view. Any obstruction will cause shadow and blind sectors.
Radar sensor Radar sensor Radar sensor Radar sensor For DRS2D/4D 1.2 Mounting Procedure for DRS2D/4D 1. Remove mounting hardware at the bottom of the radar sensor, four each of hex bolts (M10x20), spring washers and flat washers. Save the spring washers and flat washers to use them to fix the radome base to the platform, at step 3. If the thickness of the mounting platform is 5 mm or less, also save the bolts.
3. Use the hex bolts*, flat washers and spring washers removed at step 1, and fasten the radome base to the platform. The torque should be between 19.6-24.5Nzm. *If the thickness of the platform is 6-10 mm, use M10x25 bolts (supplied). For thicker platform, use locally supplied bolts. Transceiver module L Flat washer Spring washer Antenna base assy.
5. Coat the hex bolts (4 pcs.) with silicone sealant. Fasten the antenna radiator to the radiator bracket with the hex bolts, flat washers and spring washers supplied with the radiator Then, apply silicone sealant around the junction part between the radiator and bracket. 6. Apply silicone sealant to holes to prevent water ingress. Antenna radiator Radiator bracket, bottom view O-ring Radiator bracket Flat washer Spring washer Hex bolt (M8 x 30) 1.3.2 Coat threaded holes with silicone sealant.
2. Lay the radar sensor on the mounting platform, orienting it as shown below. (The hinges must face toward the stern.) BOW STERN Hinge CAUTION Do not lift the radar sensor by the radiator; lift it by the housing. The radiator may be damaged. 3. Insert four hex bolts (M12 x 60, supplied) and seal washers (φ30, supplied) from the top of the housing, as shown below. Hex. bolt Seal washer (Face projecting part down.
4. Pass flat washers (M12, supplied), spring washers (M12, supplied) and nuts (M12, supplied) onto hex. bolts. Fasten by tightening nuts. Do not fasten by tightening the hex. bolts; seal washers may be damaged. Seal washer Antenna unit Mounting platform Silicone sealant Rubber mat Flat washer 5. Coat flat washers, spring washers, nuts and exposed parts of bolts with anticorrosive sealant. 6.
Using inside fixing holes of the sensor housing If this radar is replacing a FURUNO radar whose mounting dimensions are the same as this one (140 x 150 mm), it may be possible to use its mounting platform. This method requires removal of the RF unit from the radar sensor to access inside fixing holes. Use hex bolts, flat washers, spring washers and nuts (local supply) to mount the radar sensor. 1. Unfasten four bolts from the cover to open the radar sensor. 2. Unplug the PCS connector from RF unit. 3.
1.4 Mounting of Power Supply Unit PSU-013 (for DRS25A)/PSU-012 (Option) For combinations shown below, the optional power supply unit PSU-012 (Code No.: 000-011-756) is necessary. The PSU-013 is required for any DRS25A installation. DRS2D/4D DRS4A DRS6A DRS12A MFD8 NO YES YES YES MFD12 NO NO NO YES MFDBB NO NO NO NO Contents of PSU-0012/013 Name Type Power supply unit Code No.
2. WIRING The MFDBB, MFD8, MFD12 or PSU-012 connects to the radar sensor with the two-way cable MOD-ASW0001 (MOD-ASW0002 for DRS25A).In order to minimize the chance of picking up electrical interference, avoid where possible routing the two-way cable near other onboard electrical equipment. After passing the cable through the hole in the radar sensor, apply sealing compound around the hole for waterproofing.
Wiring for DRS2D/4D/4A/6A/12A with PSU-012 Radar Sensor DRS2D/DRS4D Radar Sensor DRS4A/DRS6A/DRS12A NMEA2000 cable M12-05BFFM (f6) or CB-05BFFM (f10) Two-way cable MOD-ASW0001 (10/15/20/30 m) NMEA2000 Equipment NMEA2000 cable M12-05BFFM (f6) or CB-05BFFM (f10) (LAN) NMEA2000 Equipment (Power) Power Supply Unit PSU-012 12-24 VDC Power cable VL3P-VV-S2X2C-AA050 (supplied with PSU-012) : Standard Supply LAN cable MOD-Z072 -5 m: supplied -2, 10 m: option To ship's ground : Optional Supply : Local Su
How to terminate of NMEA2000 connection When connecting the radar sensor and an NMEA2000 equipment using the optional cable M1205BFFM (φ6) or CB-05BFFM (φ10), attach the terminator (supplied as installation materials) to the NMEA connector in the radar sensor. 1. Twist the lead wire of the resistor assembly to the cable M12-05BFFM (φ6) or CB-05BFFM (φ10), and solder them as below. Resistor assembly (120 OHM-1007#24-L150) White Twisting and soldering Blue NMEA2000 cable 2.
2.1 Wiring inside DRS2D/4D Two-way cable connection 1. Unfasten three screws at the bottom of the mounting base to remove the fixing plate for the gasket. Fixing plate (for gasket) 2. Remove the gasket, and pass the two-way cable MOD-ASW0001. 3. Fasten the shield of the cable (power) with the cable clamp in the radar sensor, and connect the connector of cable (power) to the power terminal. 4. Connect the RJ-45 connector of the cable (LAN) to the LAN terminal in the radar sensor.
6. Slide the gasket on cables so that the amount of cable above the gasket is lower than the RF chassis. This height should be lower than the RF unit when installed to the bottom of the sensor. Gasket Cable RF unit Gasket Note: If the two-way cable touches the platform near the mounting base, wind vinyl tape around the cable at the point where it is bent. 7.
5 15 Shield CB-05BFFM cable 370 Wind vinyl tape. (supplied) Fasten the cable tie (supplied) within 15 mm from the end of vinyl sheath. CB-05BFFM cable 20 65 15 (Area fastened with the cable clamp) Fabrication of CB-05BFFM cable 3. Insert wires of cable M12-05BFFM (φ6) or CB-05BFFM (φ10) to the NMEA connector inside the radar sensor, consulting the label on the connector for location. As for shield, use the cable clamp shown below.
4. Push LAN and POWER cables of the two-way cable and cable M12-05BFFM (φ6) or CB05BFFM (φ10) into the slits of the gasket inside the mounting base. Depending on the NMEA2000 cable used, replace the gasket as shown below. Cable type Gasket M12-05BFFM (φ6) CB-05BFFM (φ10) Use the gasket supplied in the plastic bag inside the radar sensor. Use the optional gasket. (Type: OP03-203, Code No.: 001-025-290) Note: The ends of the gasket are different. Larger end should be up) Large Up Small 5.
2.2 Wiring inside DRS4A/6A/12A/25A Two-way cable connection If you have no NMEA2000 equipment to connect, use the MOD-ASW0001 cable (standard supply). 1. Open the radar sensor cover by loosening four bolts, and fix the stay for safety purpose. 2. Unfasten four bolts to detach the plate, gasket, washer and lid. Discard the lid at the bottom of the hole for the gasket. Plate Gasket Washer Lid Stay 3. Pass the two-way cable MOD-ASW0001 (MOD-ASW0002 for DRS25A) through the bottom of the chassis and washer.
5. Attach the LAN cable of the two-way cable to the LAN terminal in the radar sensor. Fix the power cable at the foil part with this cable clamp. Power cable White Power terminal Black LAN cable RF unit LAN terminal DRS4A/6A/12A Fix the power cable at the copper foil part with this cable clamp. Gasket LAN cable White Power terminal Blue Red Power cable Black LAN terminal DRS25A 6.
7. Slide the gasket on cables so that the amount of cable above the gasket is lower than the RF chassis. This height should be lower than the RF unit when installed to the bottom of the sensor. Cable RF unit Gasket Gasket Washers 8. Push the gasket and washers into the hole at the bottom of the radar sensor, then fasten four pan head screws to fix the plate to the sensor. 9. Release the stay and close the cover.
the crimp-on lug (pre-attached at the bottom of the chassis) to the drain wire, and fasten it with the screw shown below. A NMEA connector view NMEA connector Crimp-on lug A Drain wire Fasten the drain wire with this screw. NMEA cable RF unit 5. Depending on the NMEA2000 used, replace the gasket as shown below. DRS4A/6A/12A Cable type Gasket M12-05BFFM (φ6) CB-05BFFM (φ10) Use the gasket supplied in the plastic bag inside the radar sensor. Use the optional gasket. (Type: OP03-205, Code No.
2.3 Wiring of Power Supply Unit PSU-013 (for DRS25A) 1. Detach the body cover by hand. 2. Loosen six pan head screws (M3x8) and slide the shield cover upward to remove it. 3. Unfasten four pan head screws (M14x10) to remove two cable clamps. Body cover Shield cover Pan head screws (M4x10, 4 pcs.) Cable clamps Pan head screws (M3x8, 6 pcs.) 4. Connect the cable VL3P-VV-S2X2C-AA50 and MOD-ASW0002 cables (supplied) to appropriate connectors in the power supply unit as shown below. 1: Red 2: N. C.
2.4 Wiring inside Power Supply Unit PSU-012 (Option) 1. Detach the body cover by hand. 2. Loosen six pan head screws (M3x8) and slide the shield cover upward to remove it. 3. Unfasten two pan head screws (M4x12) to remove the cable clamp. Body cover Shield cover Pan head screw (M4x12, 2 pcs.) Cable clamp Pan head screw (M3x8, 6 pcs.) 4. Connect the cable VL3P-VV-S2X2C-AA050 (supplied) to the power connector in the PSU012.
*': $1.6 5.166'& *'#& ⷺ㩇㩢㩦㩢 㩘㩨㩣㩎 524+0) 9#5*'4 㩔㩨㩒ᐳ㊄ (.#6 9#5*'4 㩚㩀㩨㩁ᐔᐳ㊄ 4'5+5614 #55'/$.; 㩍㨼㩄㨽⚵ຠ ฬޓޓ⒓ 0#/' %1&' 01 / : 575 %1&' 01 / 575 ޓ %1&' 01 / 575 / 575 / 575 %1&' 01 1*/ . 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105 +0 &4#9+0) (14 4'('4'0%' 10.
ᢙ㊂ 3 6; ↪ㅜ㧛⠨ 4'/#4-5 %#$.' #55; 㩃㨺㩖㩨㩣⚵ຠ %#$.' #55; 㩃㨺㩖㩨㩣⚵ຠ %#$.' #55; 㩃㨺㩖㩨㩣⚵ຠ %#$.' #55; 㩃㨺㩖㩨㩣⚵ຠ ฬޓޓ⒓ 0#/' ⇛ޓޓ࿑ 176.+0' %1&' 01 /1& #59 %1&' 01 /1& #59 %1&' 01 /1& #59 /1& #59 ဳฬ㧛ⷙᩰ &'5%4+26+105 %1&' 01 ᮡḰߪ 㨙ߢࠆ߇ᔅⷐߦࠃࠅㆬᛯน 56#0& .'0)6* +5 / 16*'4 .'0)6*5 #4' #.51 #8#+.#$.
%#$.' #55; 㩃@㩖㩨㩣⚵ຠ %#$.' #55; 㩃㨺㩖㩨㩣⚵ຠ %#$.' #55; 㩃㨺㩖㩨㩣⚵ຠ %#$.' #55; 㩃㨺㩖㩨㩣⚵ຠ ฬޓޓ⒓ 0#/' &45 # ⇛ޓޓ࿑ 176.+0' %1&' 01 /1& #59 %1&' 01 /1& #59 %1&' 01 /1& #59 %1&' 01 /1& #59 ဳฬ㧛ⷙᩰ &'5%4+26+105 ᢙ㊂ 3 6; ㆬᛯޓ61 $' 5'.'%6 ㆬᛯޓ61 $' 5'.'%6 ㆬᛯޓ61 $' 5'.'%6 ㆬᛯޓ61 $' 5'.
21/Aug/09 R.
22/Mar/08 R.
Jan.18'08 R.
D-4 2/Apr/08 R.
D-5 Oct.15'07 R.
C B 1 2 3 4 5 6 7 8 1 2 3 E_TD-P E_TD-N E_RD-P NC NC E_RD-N NC NC +48V GND SHIELD 1 2 3 +48V GND SHIELD NOTE 1. SHIPYARD SUPPLY. 2. OPTION. 3. CONNECTOR PLUG FITTED AT FACTORY. 注記 1)造船所手配。 2)オプション。 3)コネクタは工場にて取付済み。 MFD8/12 MFDBB(MPU-001) 3 4 5 6 7 8 E_RD-P NC NC E_RD-N NC NC φ7 RJ45 シロ WHT クロ BLK 12-24VDC P P P VVRx2C P *2 *3 MOD-Z072,2/5/10m,φ6(CROSS) OR RJ45 MOD-WPAS0001,3m *3 MJ-A3SPF *3 RJ45 *2 MOD-WPAS0001,3m *3 MJ-A3SPF P P 1 2 3 4 5 6 7 8 1 2 3 4 5 6 *1 DWG.No.
C B A 1 2 3 4 5 6 7 8 1 2 3 E_TD-P E_TD-N E_RD-P NC NC E_RD-N NC NC +48V GND SHIELD 1 2 3 +48V GND SHIELD *3 MJ-A3SPF *3 RJ45 *3 MJ-A3SPF NOTE 1. SHIPYARD SUPPLY. 2. OPTION. 3. CONNECTOR PLUG FITTED AT FACTORY.
C B A 3 4 5 6 7 8 *3 2 3 4 5 6 7 8 NOTE *1: SHIPYARD SUPPLY. *2: OPTION. *3: CONNECTOR PLUG FITTED AT FACTORY. *4: ATTACH A TERMINATOR. 注記 *1)造船所手配。 *2)オプション。 *3)コネクタは工場にて取付済み。 *4)ターミネータを接続する。 E_TD-N E_RD-P NC NC E_RD-N NC NC RJ45 MFDBB(MPU-001) MFD8/12 E_TD-P 1 P P P P *3 RJ45 1 2 3 4 5 6 7 8 J1 1 (+) 2 3 (-) E_TD-P E_TD-N E_RD-P NC NC E_RD-N NC NC VVRx2C *1 DWG.No. SCALE T.TAKENO T.YAMASAKI C3571-C01- D MASS kg 12/Jun/08 R.
C B A 2 3 4 5 6 7 8 12/24VDC P P P P *3 RJ45 NOTE 1. SHIPYARD SUPPLY. 2. OPTION. 3. CONNECTOR PLUG FITTED AT FACTORY.
The paper used in this manual is elemental chlorine free. ・FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN Telephone : +81-(0)798-65-2111 Fax : +81-(0)798-65-4200 All rights reserved. Printed in Japan A : JAN . 2008 B2 : JAN . 06, 2011 Pub. No.