Users Manual Part 7

3. ADJUSTMENTS
3-13
[PM GAIN ADJ]
Adjust the performance monitor,
automatically or manually, when-
ever the magnetron is replaced.
For automatic adjustment, no fur-
ther operation is required; close
the menu at the completion of the
adjustment. For manual do as
follows to adjust the performance
monitor gain.
Note: This menu is NOT avail-
able when the [RADAR] setting is
set to [SUB] for FAR-2x58 (see
"[RADAR]" on page 3-14).
1. Adjust the GAIN control so that a slight amount of white noise appears on the
screen. Arcs for the performance monitor appear on the screen.
2. Select [PM GAIN ADJ] then spin the scrollwheel so that the outer arc faintly ap-
pears. The setting range is 0 to 255 (default: 255). Wait at least eight scans then
right click to set.
Note: Turn off a stern blind sector before adjusting the PM gain, to display the
echo from the performance monitor properly.
[PM GRAPH RESET]
This menu is active only when the PM graph is shown.
Select [YES] to reset all PM graphs, after replacing the magnetron.
Note: This menu is NOT available when the [RADAR] setting is set to [SUB] for FAR-
2x58 (see "[RADAR]" on page 3-14).
[MONITOR TYPE]
The monitor type is preset at factory according to the
radar type. For BB type radar, [MU-190•231] is set in
advance. For other wide monitor, select [OTH-
ER(W)].
Note 1: [MU-231(W)] and [MU-201CR] are available only on the radars installed with
software version “01.**”
Preset the radar as follows:
Range: 24 NM
• Pulse Length: Long
A/C SEA: OFF (turn off manually)
A/C RAIN: OFF (turn off manually)
Echo Averaging (EAV): OFF
• Video Contrast: 2-B
Ex: When [ARC] is set to [5]
(The location of arcs changes with the setting of [ARC]
in [PERFORMANCE MON] in the [ECHO] menu.)
Approx. 12.1 NM (10 dB)
Before setupBefore setup
After setupAfter setup
8.1 NM to
10.1 NM
8.1 NM to
10.1 NM