Users Manual Part 7

3. ADJUSTMENTS
3-15
3.5.5 [TT PRESET] menu
Open the main menu then select [RADAR INSTAL-
LATION] [ TT PRESET] to open the [TT PRESET]
menu.
[TT DATA OUTPUT]
Show the [TT DATA OUTPUT] menu.
Note: Confirm the data input configuration for the
equipment which will receive the TT (target tracking)
sentence BEFORE setting this menu.
[SELECT SENTENCE]: Select the sentence that is
output the TT target data. (default: [TTM])
[OFF]: For no output of the TT data.
[TTM]: For connected equipment which can receive the TTM sentence.
[TTD]: For connected equipment which can receive the TTD sentence.
[TTM/TTD REFERENCE]: Set the output format for tracked target's bearing (de-
fault: [REL]).
[REL] (Target bearing from own ship, degree relative, target course, degree rela-
tive)
[TRUE] (Target bearing, degree true, target course, degree true).
[MAX RANGE]
Select the maximum target tracking range, 24, 32 or 48 NM (default: [24NM]).
Note: [48NM] is available only for the [MODEL] setting is set to [50] (see "[MODEL]"
on page 3-12).
[TT ECHO LEVEL]
Set the detection level of echoes. The setting range is 1 to 31 (default: 13).
[QV DISPLAY]
This function is used for diagnostic purposes.
[OFF]: Normal picture (default)
[ON]: Quantized video. Default setting is restored when the power is turned off.