Users Manual Part 7

3. ADJUSTMENTS
3-26
[OVERLAY1 (2)]
Note: This menu is NOT available for C-type radars.
When an ECDIS is connected, the radar picture can be
overlaid on the ECDIS. Set the items on this menu to
correctly overlay the radar picture on ECDIS.
Note: The overlay output is less accurate than the sub
monitor output from the antenna unit, especially in the
areas mentioned below. Therefore, only use the overlay
with an ECDIS.
• Distance accuracy/resolution
• Bearing accuracy/resolution
• Sweep
• Echo picture
• Range
When the echo image is NOT used with ECDIS, use the signal from the antenna unit.
[RP UPDATE]
For C-type and A/B/W radars with Radar Plotter
functionality, conduct updates for the RP board (CC6).
[APPLICATION]: Update the RP board (CC6) soft-
ware.
[OS]: Update the RP board (CC6) OS (operating sys-
tem).
[CHART SYMBOL]: Update the RP board (CC6) chart symbols.
[REMOVE USB MEMORY]: Remove a USB flash memory from the RP board
(CC6).
3.6 How to Control Charts
This section shows you how to install or update charts for C-type and A/B/W radars
with Radar Plotter functionality.
3.6.1 How to install charts
Note: Save the chart data to a USB flash memory first. You do not need to create a
folder.
1. Connect the USB flash memory with chart data to the USB drive from the RP
board.
2. Press the MENU key to open the main menu.
3. Select [INITIAL SETTINGS].
4. Select [UPDATE CHART]. The following message appears.
RP UPDATE
APPLICATION
OS
CHART SYMBOL
REMOVE USB MEMORY
OTHER FUNCTIONS WILL STOP DURING
THE CHART UPDATE.
ARE YOU SURE?
㻾㼁㻺䚷䚷䚷㻌㻌㻌㻌㻌㻯㻭㻺㻯㻱㻸