Users Manual Part 7

2. WIRING
2-71
2.10.4 How to check the installation
Observe the LEDs on the converter to check for proper operation and troubleshooting.
Note: The TEST button is for factory use. Do not operate the button.
2.11 Junction Box (option)
For X-band radar of FAR-2x18/2x28/2x38
radars, the Junction boxes are required
when the distance between the antenna unit
and processor unit is greater than 100 me-
ters (max. 460 meters); for example, the an-
tenna unit is installed on the foremast. Use
signal cable RW-9600 (2), power cable
DPYCY-6 (3), and coaxial cable RG-12/
UY(3).
Pass each cable through its cable gland as
shown to the right.
LED State Meaning
PWR OFF Power OFF
Lighting green Power ON
Flashing orange Test mode
LAN OFF Link down
Lighting green 100 M link up
Flashing green 100 M active
Lighting orange 10 M link up
Flashing orange 10 M active
Coax/PLC OFF Link down
Lighting green Link up
Master/Slave Lighting green Master mode
Lighting orange Slave mode
Master/Slave
Coax/PLC
LAN PWR
TEST
M S
HMC-200CE-A
Flat washer
Cable gland
Vinyl sheath
Clamping
gland
Gasket
Cut and trim armor.