Users Manual Part 8

7. MAINTENANCE, TROUBLESHOOTING
7-13
(Continued from previous page)
[MTR] [MOTOR ROT
SPEED]
Other than FAR-2x58:
0 (STBY)/24/36/42
FAR-2x58:
TBD
[ERROR STATUS] Blank indicates no errors.
When an error is found, the relevant error code appears.
[PM] [12V] 9 to 15 Volts
[PLL STATUS] Other than FAR-2x58:
For X-Band (with board revision
number 1 or earlier) and S-Band
(with board revision number 0):
UNLOCK
For X-Band (with board revision
number 2 or later) and S-Band
(with board revision number 1 or
later):
PM activated: LOCK
PM inactive: UNLOCK
FAR-2x58:
PM activated: LOCK
PM inactive: UNLOCK
PM activated: LOCK
PM inactive: UN-
LOCK
[PSU]* [TB 12V] 9 to 15 V
[TB -12V] -15 to -9 V
[TB HEATER H] 9 to 15 V
[TB 5V] 4.5 to 5.5 V
[MONI TX HV] 760 to 820 V
[TB N5V] -5.5 to -4.5 V
*: Appears for FAR-2x58 only.
Tested item
Normal value or Description
Magnetron Radar Solid State Radar