Users Manual Part 6

FURUNO
FAR-2xx8 SERIES
SP - 3 E3652S01L-M
191029
Vector time: Off, 30 s, 1-60 min
3.12 Echo trail True/Relative, Trail length: 0 to 30 minutes (30 s steps) or continue
Maximum 48 hours setting available for B/W-type radar
3.13 Radar map 20,000 pts
3.14 Acquisition zone 2 zones
3.15 Interswitch function Selectable from menu
4 MONITOR UNIT
4.1 Screen type
MU-190 19-inch color LCD, 1280 x 1024 (SXGA)
MU-231 23.1-inch color LCD, 1600 x 1200 (UXGA)
MU-270W 27-inch color LCD, 1920 x 1200 (WUXGA)
4.2 Brightness
MU-190 450 cd/m
2
typical
MU-231/270W 400 cd/m
2
typical
4.3 Visible distance
MU-190/270W 1.02 m nominal
MU-231 1.2 m nominal
4.4 Radar effective diameter
MU-190 282 mm
MU-231 331 mm
MU-270W 349 mm
5 INTERFACE
5.1 Number of port (processor unit)
Serial 7 ports (IEC61162-1/2: 2 ports, IEC61162-1: 4 ports, AD-10: 1 port)
Alarm output 6 ports: contact signal, load current 250mA
(Normal close/ open: 4, System fail: 1, Power fail: 1)
DVI output 2 ports: DVI-D, DVI-I or RGB picture data (for VDR)
(RGB resolution 1280x1024 (SXGA), 60.0Hz or
1440x900 (WXGA+), 59.9Hz)
LAN 2 ports: Ethernet 100Base-TX
RS-232C 1 port: brilliance control
Sub display (for ECDIS) 2 ports: HD, BP, Trigger and Video signal
5.2 Data sentences (IEC61162-1/2)
Input ABK, ACK, ACN, ALR, BWC, BWR, CUR, DBK*
1
, DBS*
1
, DBT,
DDC, DPT, DTM, GGA, GLL, GNS, HBT, HDT*
1
, MTW, MWV,
OSD, RAQ, RMB, RMC, ROT, RTE, THS, VBW, VDM, VDO,
VDR, VHW, VSD, VTG, VWR*
1
, VWT*
1
, WPL, ZDA
Output ABM, ACK, AIQ, ALC, ALF, ALR, ARC, BBM, DDC, EVE, HBT,
OSD, RSD, TLB, TLL*
2
, TTD, TTM, VSD
*
1
: for retrofit. *
2
: for B/W-type radar
5.3 Ethernet interface for IEC61162-450
Port (LAN2) 100Base-TX, IPv4, 8P8C connector
Data sentences Same as 5.2 sentences
IEC61162-450 transmission group
Input MISC, TGTD, SATD, NAVD, TIME, PROP
Output Arbitrary (default: TGTD)