Users Manual Part 6

2. WIRING
2-65
3. Fasten the cables to the post part of the plates with cable ties (local supply).
Note: Be sure the vinyl sheath on the post.
4. Pass the cables to the TB board 03P9648 and
03P9562 through the locking wire saddles (A, B and
C) in the figure shown right.
For the cables on the upper plate, use locking wire
saddles (A and B).
For the cables on the lower plate, use locking wire
saddles (A, B and C).
5. Connect the connectors to the TB Board. referring to
the interconnection diagram.
6. Connect the ground wires of cables to the near ground terminals on the plates.
Connection of cables for Control Unit
1. Unfasten the four bolts, indicated with dashed circles below, to remove the upper
plate of the cable clamp.
Spacer
Cable tie
Ground termimal
Ground termimal
Cable tie
Vinyl
sheath
Shield
Cable tie
Sub monitor cable
Serial cable
Vinyl
sheath
Upper plate Lower plate
(
B
)
(
C
)
03P9648
03P9652
(
A
)
J620
(AD-10, GYRO)
J618 (AMS serial) J615 (AIS)
J621
(RS-232C for brill control)
J611
(Control Unit)
J619 (ECDIS)
J613 (AMS contact)
J608 (Antennna)
J503
Connect LAN cable
for antenna cable.
J510/J511
Connect cable for sub
monitors of ECDIS.
J508
Connect cable for USB mouse or USB keypad (local supply, max. 5 m).
Note:
Do not connect a USB device other than mouse.
J617
(LOG)
J616
(GPS)
J614
(HDG)