2. WIRING
2-68
2.9 Monitor Unit
For the wiring of the monitor unit, see the operator’s manual supplied with the monitor
unit.
Mounting considerations
Standard type
Connect the radar main monitor to the DVI1.
Connect the sub radar monitor to the DVI2.
VDR connection
To connect a VDR, it is necessary to output data in analog format. To connect a
VDR to the DVI-I port, use the optional DVI-BNCX5+GND-L2.0 cable to output the
RGB signal from the DVI-I. See the operator’s manual supplied with the VDR. Ad-
justment of the output is necessary.
Menu Setting
The [INSTALLATION SETTING] menu appears only when the power is turned on for
the first time after installation of the monitor unit.
Adjust the settings referring to the following table.
*: [DVI PWR SYNC] is the slide switch at the bottom rear of the monitor unit. Confirm
that this switch is set to [ON] (default setting). See Slide switch below for details.
Slide switch
Set the slide switch to "ON" (default setting). This setting automatically powers the
monitor unit on or off according to the DVI signal input. The power switch of the mon-
itor unit is inoperative.
Note: The OFF position provides control of the monitor unit power with the power
switch of the monitor unit.
EXT BRILL
CTRL
COLOR
CALIBRATION
KEY
LOCK
DVI PWR
SYNC*
DVI OFF ON ON
INSTALLATION SETTING
EXT BRILL CTRL
SERIAL BAUDRATE
COLOR CALIBRATION
KEY LOCK
SAVE AND EXIT
RS-485
4800bps
ON
ON
YES
(OFF/DVI1/DVI2/RS-232C/RS-485/USB)
(4800/9600/19200/38400)
(OFF/ON)
(OFF/ON)
(NO/YES)
Menu
Menu item