User's Manual

29
REG00: Local Station Address [default value: 000]
Sets the local station address. Valid values are 000 to 999.
This value is inserted in the “source address” field in the transmitted packet header.
If the address check function is enabled (REG18) in the receiving modem, the
modem can receive the packet which header contains destination address
information identical to REG00.
REG01: Local Station Group Address [default value: 240]
Sets the local station global address of the modem. Valid values are 240 to 254.
When plural modems are connected by RS485 multi-dropping topology, commands
can be issued to multiple modems simultaneously by setting all connected modems to
the same group address. This is the group addressing.
This group addressing allows to handle multiple multi-dropped modems as if they
were one modem.
REG02: Destination Address [default value: 000]
This address is used in the data transpalent mode and headerless stream mode.
Valid values are 000 to A23(1023).
REG03: Reserved [default value: F0H]
The FDL01TU does not use this register. Keep the default value as it is.
REG04: ID Code 1 [default value: 00H]
Used with ID code 2 (REG05), set the ID code. Valid values are 000 to 255.
Together with ID code 2, up to 65535 ID codes can be set.
The ID code identifies the group of the modems works in the same group. The ID
code is used to prevent erroneous connection with other systems and for
communication security.
Before transmission, radio data packets are scrambled using a pseudo-random data
sequence generated with this ID code as the seed. During reception, the original data
is restored by de-scrambling it with the pseudo-random data sequence. The modems
with different ID codes cannot communicate with each other.
REG05: ID Code 2 [default value: 00H]
Used with ID code 1 (REG04), set the ID code. Valid values are 000 to 255.
Together with ID code 1, up to 65535 ID codes can be set.
In case plural modems are used as a single system, always set the same ID code for all
modems and repeaters.