User's Manual

49
Example
>
@
FRQ
CR/LF
: reference the current grouping method and frequency
number
<F00
CR/LF
: output current value (grouping method F: group number 00)
>@FRQ:E03
CR/LF
: set grouping method to E (6 groups) and group number to
3.
<P0
CR/LF
: command accepted
Method
Group Numbers
Frequencies
per Group
A 0
to
75
1
B 0
to
37
2
C 0
to
24
3
D 0
to
18
4
E 0
to
11
6
F 0
to
8
8
G 0
to
5
12
Table 3–7: Frequency Grouping Methods and Group Numbers
Notes
Do not change this setting while the modem is being transmitted.
The maximum number of frequency groups available depends upon the selected
grouping method.
INI Initialize All Memory Registers
Syntax
INI{Local Station Address}
Local Station Address : local station address for 485 mode (000 to A22).
Response
P0 : command accepted
N0 : command error (Except 485 mode)
Function
Sets the all contents of the memory registers to the factory default values.
Example
>
@
INI
CR/LF
: initialize all memory registers
<P0
CR/LF
: command accepted
Notes
Custom settings of all memory registers are lost when this command is executed.