User's Manual
51
This command enables serial data output after it has been disabled with the ODA
command.
When the modem’s power is turned on (or a reset), the modem is in the state to
enable the received data output.
Example
>
@
ODA
CR/LF
: disable serial output of received wireless data
<P0
CR/LF
: command accepted
(Data is not output during this period even if received.)
>
@
OEN
CR/LF
: enable serial output of received wireless data.
<P0
CR/LF
: command accepted
<RXT002HELLO
CR/LF
: outputs data stored in receive buffer
<RXT003MAIL
CR/LF
: and any new data received
PAS Reference and Set Repeater Address
Syntax
PAS (:Repeater Address1 :Repeater Address2)
Repeater Address : repeater address to pass through
Response
xxx : xxx : current address (reference)
P0 : command accepted (setting)
N0 : command error
Function
In the headerless stream mode , references and sets the repeater address to
pass through
When no repeater address is set, the current setting can be referenced.
This command is used to temporarily change repeater address. To change the
default value, change REG13.
Example
>
@
PAS
CR/LF
: references the current repeater address
<004 : A00
CR/LF
: current repeater address is 004
<P0
CR/LF
: command accepted
<
@
PAS:002:A00
CR/LF
: sets the repeater address to 002
<P0
CR/LF
: command accepted
Notes
This command is not allowed to be used in 485 mode.