User's Manual

Ver.1.0
34
IDR (Show ID code)
[Format]
IDR
[Response]
xxxxH: Current setting value
(It is the value of REG04 and REG05 right after turned ON the main power.)
[Function]
- This command shows the ID code.
[Example of use]
>@IDR<Cr><Lf>: This command shows the ID code.
<0000H<Cr>Lf>: This response indicates the current ID code is “0000H”.
IDW (Set ID code)
[Format]
IDW
Available setting value: “0000H” to “FFFFFH”
[Response]
P0: Normal end
N0: Command error
[Function]
- This command can change ID code temporarily. For permanent change, REG04 and REG05 should be
changed.
[Example of use]
>@IDW1234H<Cr><Lf>: This command set ID code to 1234.
<P0<Cr>Lf>: Normal end.