RST :Reset
【Format】
RST
【Response】
P0 : normal termination
N0 : command error
【Function】
・This module will be reset.
TLC :Set wireless data
【Format】
TLC[binary data]
Binary data : 60-bytes fixed
【Response】
None
【Function】
・It specifies the data you want to send to the communication partner. It is 60-bytes fixed in
binary data.
・In order to avoid the mixing of the received data, there is no response to this command.
・Input of this command, please as a 50ms interval at the shortest.
VER : Display version
【Format】
VER
【Response】
Program Version 1.000 : display version
N0 : command error
【Function】
・Reads a program version of the wireless module.
・X.XXX
Improvements and bug fixes within a range of specifications
Minor specification change
Major specification change