Instruction Manual

Tentative
14
FHE: End FH operation
Format
FHE
Response
P0 : normal termination
N0 : command error
Function
End FH operation. At this status, wireless transmission does not occur.
Master/Slave stops radio transmission and reception. If state that FH synchronization acquisition,
and then release it.
Even when there is received data from a paired module, wired output does not occur.
FHS Starts FH operation
Format
FHS
Response
P0 : normal termination
N0 : command error
Function
Starts FH operation.
Master/Slave starts radio transmission and reception.
When there is received data from a paired master, wired output starts.
If there is data received from pairing the communication partner, to start the output to the
wired.
ID Reference and set pairing ID1
Format
ID2(:pairing ID code 1)
pairing ID code 1 : xxxxxxxxx9-digit
Response
xxxxxxxxx : pairing ID code 1 (when when referencing)
P0 : normal termination (when setting)
N0 : command error
Function
References and sets the pairing ID code 1.
By inputting only the command, currently set values can be referenced.
Specify the ID code (9-digit Serial Number) of the module that is the communication partner.
Both master and slave are valid.
The setting becomes effective after a reset.