Instruction Manual
Tentative
15
ID2 :Reference and set pairing ID2
【Format】
ID2(:pairing ID code 2)
pairing ID code 2 : xxxxxxxxx(9-digit)
【Response】
xxxxxxxxx : pairing ID code 2 (when when referencing)
P0 : normal termination (when setting)
N0 : command error
【Function】
・References and sets the pairing ID code 2.
・By inputting only the command, currently set values can be referenced.
・Specify the ID code (9-digit Serial Number) of the module that is the communication partner.
・Slave only is valid.
・The setting becomes effective after a reset.
IDS :Start ID registration
【Format】
IDS:[pairing area]
pairing area : x (1= pairing ID code 1, 2= pairing ID code 2)
【Response】
P0 : normal termination
Pair : pairing is completed
N0 : command error, or pairing is not completed
N6 : memory register writing error
【Function】
・Starts pairing operation.
・In the case of master, please specify '1' to the pairing area.
・In the case of slave, please specify '1' or '2' to the pairing area.
INI : Initialize register value
【Format】
INI
【Response】
P0 : normal termination
N0 : command error
【Function】
・Resumes all contents of the memory register in the wireless module to the status at factory
shipment.