Instruction Manual

Tentative
16
ODA Disable output
Format
ODA
Response
P0 normal termination
N0 command error
Function
Disable the radio transmission and wired output. Temporarily used when you want to stop FH
communication. If this module already has FH synchronization acquisition, also it will continue
to maintain FH synchronization after executing this command.
Output in the initial state is enabled.
Slave only.
OEN Enable output
Format
OEN
Response
P0 normal termination
N0 command error
Function
Enable the radio transmission and wired output.
Output in the initial state is enabled.
Slave only.
REG Reference and set register values
Format
REG[register number](:set value)
Register number : 00XX
Set value : input a two-digit hexadecimal number with H at the end,
or a three-digit decimal number without any suffix.
Response
XXX : currently set value (when referencing)
P0 : normal termination (when setting)
N0 : command error
N6 : memory register writing error
Function
References and sets the memory register.
By inputting only a register number, currently set values can be referenced.
The setting will be valid after reset.