Instruction Manual
Tentative
21
Bit2~0:Baud rate setting
Table 12:Baud rate
Bit2
Bit1
Bit0
Baud rate
0
0
0
19200bps
0
0
1
115200bps (default)
0
1
0
Reserved
0
1
1
Reserved
1
0
0
Reserved
1
0
1
Reserved
1
1
0
Reserved
1
1
1
Reserved
REG09:Wired communication setting 2 [default:00H]
Bit7~5:Reserved
* Not used in this machine. Make sure to set to 0.
Bit4:Addition and deletion of CRLF
Table 13:Addition and deletion of CRLF
0
Do not add the CR+LF code to the receive data. (default)
1
Add the CR+LF code to the receive data.
* Sets whether adding the CRLF code or not to the received data.
Bit3~0:Reserved
* Not used in this machine. Make sure to set to 0.
REG10~11:Reserved [default:00H]
* Not used in this wireless module. Leave default setting.
REG12:Detailed setting [default:08H]
Bit7:Startup message output
Table 14:Startup message output
0
Disable startup message output (default)
1
Enable startup message output
* When you want to output message at startup, set to 1 in this bit.
* At startup, “Input command” is output to the wired. By this message, you can recognize the
activation timing.
Bit6~4:Reserved
* Not used in this machine. Make sure to set to 0.
* No function assignment.