Press
Press
Press
Select
"FAIL SAFE"
Press
(HOME screen)
(MENU 2 screen) (
FAIL SAFE
screen)(MENU 1 screen)
cursor position [RT]
Setting item
MODE :F/S mode selection
POSI :F/S positon set
B-FS :B-FS set (throttle only)
VOLT :B-FS voltage set (throttle only)
49
Function
Fail Safe Function "FAIL SAFE"
Fail Safe Function "FAIL SAFE"
(All channel)
Fail Safe Mode (F/S)
This function moves each servo to a preset position when the receiver cannot receive the
signals from the transmitter for some reason.
-When the condition set at "FHSS" is Rx type (P29), fail safe (F/S) can be set only for throttle (TH). Other channels are set to
the normal mode.
-The fail safe data is transferred from the transmitter to the receiver 10 seconds after the transmitter power was turned on.
7KHGDWDLVWUDQVIHUUHGHYHU\VHFRQGVDIWHUWKDW%HFDUHIXOEHFDXVHQRUPDOO\WKHWUDQVPLWWHUSRZHULVWXUQHGRQ¿UVWDQGWKH
receiver power is turned on next and the data is transferred for approximately 10 seconds after the receiver power is turned
on.
-For gasoline engine cars, for safety we recommend that this fail safe function be used to set the throttle channel in the direc-
tion in which the brakes are applied.
Hold mode (HOLD)
This function holds the receiver in its position immediately before reception was lost.
It is the T-FHSS typ (R304SB...etc) and the S-FHSS type (R2104GF...etc) receiver only
function. When the receiver used is the R603GF/R2004GF and other FHSS type, this
function cannot be used because the receiver type is set to
"
FHSS
"
by Rx type setting
Off mode (OFF)
This function stops output of signals to the servos and places the servos into the free
state when the receiver cannot receive.
The F/S, HOLD, and OFF modes are automatically reset when signals from the trans-
mitter can be received again.
Battery fail safe function (BFS)
If the receiver battery voltage drops below a certain value when this function is enabled,
the throttle servo moves to the position set by fail safe function. When the battery volt-
age recovers, the battery fail safe function is automatically reset.
-This function cannot be used when the throttle (TH) is not set to fail safe (F/S).
-This function is for the T-FHSS typ (R304SB...etc) and the S-FHSS type (R2104GF...etc) receiver only. It cannot be used
with the R603GF and R2004FG and other FHSS type.
Display to "FAIL SAFE" screen by the following method:
4PLS-Eng-08-1-Function-P39-64.indd 49 2013/04/07 12:40:56