INI All Memory Registers Initialize
Syntax
INI{Local Station Address}
Local Station Address : local station address for 485 mode (000 to 254).
Response
P0 : command accepted
N0 : command error (Except 485 mode)
egisters
otes
ss (240 to 254) is designated while RS485 multi-drop connection
of all modems will be
initialized to 000. Exercise care when issuing this command.
For a list of the factory default values, see the section titled p.59 MEMORY
Function
Sets the all contents of the memory registers to the factory default values.
Example
>@INI CR/LF : initialize all memory r
<P0 CR/LF : command accepted
N
Custom settings of all memory registers are lost when this command is executed.
If the global addre
is being made in the RS485 mode, the local station address
REGISTER DESCRIPTION.