User's Manual

Page 78 FRH-SD07TU/TB Manual
REG27: Frequency Band Setting [default value: 01H] s
Bit 7 – 6: reserved
The FR -S r. Keep the default value as it is.
Bit 5 – 4: Output clock ra
Bit 5 Bit 4 Setting
H D07TU/TB does not use this registe
te of AUX terminal
0 0 No clock output (default value)
0 1 100KHz
1 0 1.14MHz
1 1 8MHz
Table 5–30: Setting of output clock rate of AUX terminal
Sets the operation clock rate of the output signal of the AUX terminal for the status
ires
hig
clo ption.
or the function of the AUX terminal, refer to p.151 AUXILIARY INTERFACE
monitor use. Some of the status data contains high speed one-shot signals, which requ
h speed clock to properly catch. Because of higher current consumption when higher
ck rate, this parameter controls the clock rate to decrease current consum
F .
B 3it – 0: Frequency band setting
Bit 3 Bit 2 Bit 1 Bit 0 Setting
0 0 0 0 Invalid (forced to 0001)
0 0 0 1 2433-2479MHz (default value)
0 0 1 0 Do not set (Invalid)
0 0 1 1 01 Band
0 1 0 0 02 Band
0 1 0 1 2420-2466MHz 2MHz Separation
0 1 1 0 2423-2469MHz 2MHz Separation
0 1 1 1 Reserved
1 - - -
Table 5–31: Frequency band setting
For the frequency band, refer to p.35 FREQUENCY BAND
.
For the FRH-SD07TB users in France and Spain, frequency usage is restricted to 02
Band because of its country’s regulatory authority. Also please refer p.35 FREQUENCY
BAND for its details.
Rev. 050415-01.1