SBD-1 S.Bus Decoder - Manual

WARNNG
Always use in the state in which the SBD-
1 is firmly attached to the fuselage of
the airplane or helicopter. There is the danger
of loss of control and crashing if the connector is
disconnected by vibration and shock.
CAUTION
When using analog servos, always use in
the state in which the receiver is normal
mode. There is the danger of erroneous operation
or damage on the high speed mode.
Do not connect any device (gyro, battery,
etc.) other than servos to the servo
connector of the SBD-1. There is the danger of
erroneous operation or damage.
Do not connect an S.BUS connector
of the SBD-1 to other than an S.BUS
connection port. There is the danger of
erroneous operation or damage.
Futaba Corp. will not be responsible for
damage caused by combination with other
than Futaba Genuine parts.
S.BUS Decoder
INSTRUCTION MANUAL
Before using your SBD-1, please read this manual thor-
oughly and use the system properly and safely.
After reading this manual, store it in a safe place.
•Channel setting by SBC-1
1
Connect the S.BUS connector of the SBD-
1 to the S.BUS servo connection port of the
SBC-1.
2
Connect the battery to the battery connec-
tion port of the SBC-1.
* Status display LED blinks slowly. (About 1 sec/time)
3
Quickly press and release the SBC-1setting
switch and select the servo connection port
at which the channel is to be set.
* Each time the switch is pressed, the set servo
connection port and the number of times the LED
blinks change.
SBC-1
SBD-1
servo
connector selec-
tion
Setting switch
operation
LED display
When power
turned on
1 short blink
each second
Connector (
SX1
)
selected.
Switch pressed
and released
quickly
2 short blinks
each second
Connector (
SX2
)
selected.
Switch pressed
and released
quickly
3 short blinks
each second
Connector (
SX3
)
selected.
* &KDQQHOFRQ¿UPDWLRQ
When the operation position of the channel selector
switch and the channel set at the connector during
the
SBD-1
servo connector selection coincide, the
LED changes to a steady light.
4
Set the SBC-1 channel selector switch to
the channel you want to set.
5
Hold down the setting switch (about 1 sec-
ond).
©Copyright 2017. No part of this manual may be reproduced in any form without
prior permission. The contents of this
manual are subject to change without prior notice. While this manual has been carefully written, there may be inadvertent
errors or omissions. Please contact our service center if you feel that any corrections or clarifications should be made.
FUTABA CORPORATION oak kandakajicho 8F 3-4 Kandakajicho, Chiyoda-ku, Tokyo 101-0045, Japan
TEL: +81-3-4316-4820, FAX: +81-3-4316-4823
©FUTABA CORPORATION 2017, 4 (3)
Meaning of Special Markings
Pay special attention to safety where indicated by the following marks:
DANGER
Procedures which may lead to dangerous conditions and
cause death/serious injury if not carried out properly.
WARNING
Procedures which may lead to a dangerous condition or
cause death or serious injury to the user if not carried out
properly, or procedures where the probability of superficial
injury or physical damage is high.
CAUTION
Procedures where the possibility of serious injury to the user
is small, but there is a danger of injury, or physical damage,
if not carried out properly.
= Prohibited = Mandatory
Usage Precautions
Name of Each Part and Accessories
Channel Setting
Usage Method
•Connection
1
Connect the S.BUS connector of the SBD-
1 to the receiver S.BUS connection port or
S.BUS hub.
2
Connect a conventional servo or an S.BUS
servo to the servo connector of the SBD-1.
* When an
S.BUS
servo was connected, that servo
will operate as a conventional servo. However,
it operates on the channel set at the servo
connector of the
SBD-1
instead of the channel set
at the servo itself.
Thank you for purchasing an
SBD-1
,
S.BUS
*1
decoder.
The
SBD-1
is a converter for using conventional servos
(other than
S.BUS
servo
*2
) with the
S.BUS
system.
*1
S.BUS
: Serial communication system for Futaba R/C system
*2
Use the
S.BUS
hub as the extension code used for the
S.BUS
servo.
Also
SBD-1
can be used.
Before installing the
SBD-1
to the fuselage, set
each channel at each servo connector (
SX1
~
3
).
The equipment by which a channel set is possible
SBC-1
S.BUS channel changer
CIU-2/3
USB adapter (
SBD-Link
software for
setting)
T6K,T10J,T14SG(V4.0-),FX-22(V4.0-
*
S.BUS
decoder channel setting is impossible with
the
S.BUS
receiver
R6108SB
.
*
SBD-Link
software can be downloaded from the
home page of your region's Futaba importer.
Conventional servo
(or S.BUS servo)
to the receiver
S.BUS
con-
nection port or
S.BUS
hub
SX1
SX2
SX3
SBD-1
6HUYRFRQQHFWRU
(Upper)
SX1
(Middle)
SX2
(Lower)
SX3
6%86FRQQHFWRU
[SBD-1 Ratings]
Dimensions:
41.8x12.3x8.4mm
(1.65x0.48x0.33in.)
(excluding protruding)
Power requirement:
NiCd, NiMH 4 to 5 cells
equivalent battery (Futaba)
Operating temperature
range: -10 to +45
* During channel setting, the LED blinks quickly
(about 5 times/sec). When the LED changes to a
steady light, channel setting is complete.
6
To set the channel of other servo connec-
tion ports, quickly press and release the
setting switch and repeat steps 4 and 5.
<Accessories>
Channel Number Label
Put the channel number label on the servo con-
QHFWRUIRUWKHLGHQWL¿FDWLRQRIFKDQQHOQXPEHU
Instruction manual (this manual)
Applicable receiver: S.BUS system
receiver only
SBD-1 is not compatible with S.BUS2
1M23N23403

Summary of content (1 pages)