Instruction Manual
- 6 - 
Tel: (949) 465-0900 
Fax: (949) 465-0905 
Toll Free: (800) 23 FUTEK 
shunt
excitation
polarity
bandwidth
gain
SW1
SW2
SW4
SW5
current setting
SW8
SW6
current input range
SW7
SW3
Excitation 
There are two excitation values available on the CSG110: 10 VDC (default), and 5 VDC. 
To select the excitation, simply flip the DIP switch to the appropriate configuration. 
The excitation voltage controls the maximum output of the amplifier. 
Ex. If your application requires a lower output voltage than 10 VDC, then the 5 VDC 
option is available to use. All you have to do is flip the DIP switch from the down 
position to the up position. 
UP 5
DOWN 10
SW1: Excitation (VDC)
Polarity 
There are two polarities available on the CSG110: reverse, and straight (default). To 
select the polarity, simply flip the DIP switch to the appropriate configuration. 