Manual

15.RS-485 COMMUNICATION INTERFACE(OPTION)
96
15. RS-485 COMMUNICATION INTERFACE(OPTION)
15-1. Communication Specifications
- Specifications
Signal level Based on RS-485
Transmitting distance Approx 1km
Transmitting method Asynchronous󲃙Full duplex
Transmitting speed 1200󲃙2400󲃙4800󲃙9600 or 19200bps Selectable
Bit configuration Start 1bit
Character length 7 or 8bits Selectable
Stop 1 or 2bits Selectable
Parity None,Odd or Even Selectable
Terminator CR+LF/CR Selectable
Code ASCII
- Connector Pin Assignment
15-2. RS-485 connection
1.Connection of transmitting and receiving lines
4-wire connection
Set the communications mode of the F371 to “4-wire.”
Connect the “SD” (sending side) of the equipment on the other end (master), such as a
programmable controller, to “RD” (receiving side) of the F371 (slave), and “RD” of the
master to “SD” of the F371.
MARK󲃕OFF󲃖
VA-VB < -0.2V
SPACE󲃕ON󲃖
VA-VB > 0.2V
A 󲃚
B 󲃘
A 󲃚
B 󲃘
SD
RD
SG