Installation Manual
Table Of Contents
- Foreword
- Product Safety and RF Exposure Compliance
- Before using this product, read the operating instructions for safe usage contained in the Product Safety and RF Exposure booklet enclosed with your radio.
- ATTENTION!
- This radio is restricted to occupational use only to satisfy FCC RF energy exposure requirements. Before using this product, read the RF energy awareness information and operating instructions in the Product Safety and RF Exposure booklet enclosed wi...
- For a list of Motorola-approved antennas, batteries, and other accessories, visit the following website: http://www.motorola.com/governmentandenterprise
- Document Copyrights
- Disclaimer
- Trademarks
- Spectrum Series™ Base Loaded Mobile Antennas Installation Manual
- Spectrum™ Series Base Loaded Mobile Antennas
- Introduction
- Mobile Antenna Installation
- Spectrum™ by Motorola
- Spectrum™ by Motorola
- Product Safety and RF Exposure Compliance
Mobile Antenna Installation 9
Mini-UHF Connector Installation #28-84606M01
Installation Instructions
Use Motorola tool part # 66-80388A26 (Refer to Figure 8).
1. Slip ferrule and collar onto cable. See Figure 10.
2. Prepare cable to strip dimensions as per Figure 11.
3. Insert stripped cable into plug body until conductor is exposed (front end) and dielectric
bottoms inside body. See Figure 10.
4. Crimp center contact using crimp area C of Figure 8 . Crimp at base of center contact, avoid
crimping at the tip. Refer to Figure 9.
5. Push collar forward onto plug assembly. Fit cable braid over support sleeve of connector. See
Figure 10.
6. Push ferrule over braid until flange butts against connector body. Refer to Figure 10. Using
the correct crimp area of tool, crimp ferrule close to plug body. Crimp ferrule for a second time
close to cable end.
7. Protuding center conductor should be trimmed with end of center contact.
Figure 8. Motorola Crimping Tool 66-80388A26
.256
.319
.068
.051
.213
A
B
C
D
E
FIVE CRIMP AREAS