F u tu ro F u tu ro Skylight Designer range hood 54” version LIBRETTO ISTRUZIONI INSTRUCTIONS BOOKLET GEBRAUCHSANWEISUNG MODE D'EMPLOI MANUAL DE INSTRUCCIONES ИНСТРУКЦИИ INSTRUKCJA OBSŁUGI GEBRUIKSHANDLEIDING MANUAL DE INSTRUÇÕES BRUGSANIVSNINGER INSTRUKTIONSBOK OHJEKIRJA BRUKSANVISNING 1
BLOWER LOCATION OPTION 1: Blower installed directly on hood Blower chamber may be installed with opening facing any direction OPTION 2: Blower installed in remote location (attic, garage, etc) 6" round, RIGID duct (do NOT use exible duct!) Duct Adapter (included) TOOLS NEEDED ø9 mm 2
BLOWER BOX DIMENSIONS 12" 6" 11" 5 1/2" 9 3/4" 11" 6" 9 3/4" 12" 11" 11" 4" 3
DIMENSIONS IF BLOWER IS MOUNTED ON HOOD 3D OVERVIEW CUTOUT DIMENSIONS 23 1/4" 52 3/16" BOTTOM VIEW SIDE VIEW 11" 13 3/4" 10 3/4" 53 1/2" 11" SIDE VIEW 1/2" min 1" max 6" 5" 4" 24 5/8" TOP VIEW 25 3/16" 22 3/4" 14 1/2" 51 9/16" 4
DIMENSIONS IF BLOWER IS MOUNTED REMOTELY (ATTIC/GARAGE) 3D OVERVIEW CUTOUT DIMENSIONS 23 1/4" 52 3/16" BOTTOM VIEW SIDE VIEW 6" 5 1/4" 53 1/2" 1/2" min 1" max SIDE VIEW 5" 4" 24 5/8" TOP VIEW 22 3/4" 51 9/16" 5
INSTALLATION - BLOWER ON HOOD - FC 1 2 FM UM 3A FL FLF 4 (x2) SM AIR AIR AIR 3B (x2) UM SM FL FLF 6
H1 INSTALLATION - BLOWER ON HOOD 150mm 940 CFM UM 1 ø 15 2 G F V3 6 5 4 OK! Smontaggio! Disassembly! 3 G (x2) During installation, chains or cables may be used to TEMPORARILY support the hood. Permanent installation requires secure attachment to load-bearing elements (joists/frame/soft box) with screws or bolts.
INSTALLATION - REMOTE BLOWER R FC 3 150mm (x2) F 2 F FC 5 2 G CUE 1 6 4 G Smontaggio! Disassembly! CUE V3 S1 OK! 8
INSTALLATION - REMOTE BLOWER During installation, chains or cables may be used to TEMPORARILY support the hood. Permanent installation requires secure attachment to load-bearing elements (joists, wooden frame, or soft box) using screws or bolts.
FILTER & LIGHT BULB REMOVAL/REPLACEMENT T MAGNETE - MAGNET 1 U 1 3 2 V 2 M 3 1 N 10
SAFETY INSTRUCTIONS AND WARNINGS INTENDED USE • INSTALLATION WARNINGS TECHNICAL SAFETY • Installation operations are to be carried out by skilled and qualiied installers in accordance with the instructions in this booklet and in compliance with the regulations in force. • • • • • • • • Before installing the hood, check the integrity and function of each part. Should anomalies be noted, do not proceed with installation and contact the Dealer.
Before connecting the equipment to the electrical mains power supply, check that: • voltage supply corresponds with what is reported on the identiication plate located inside the hood; • the electrical system is compliant and can withstand the load of the equipment (refer to the technical speciications on the identiication plate located inside the hood); • once connected, the plug and cable do not come into contact with hot parts having temperatures that exceed 70°C • the power supply system is efectively a
REMOTE MOTOR UNIT The hood can be connected to the under-roof remote motor unit. In the case of an under-roof motor unit ( URS), it must be placed next to the technical compartment inside the home, protected against atmospheric agents and within reach for any maintenance operations. In the case of installation with remote motor, you must connect the hood to the electrical system earthing (after having veriied its functioning) by means of a suitable cable. Phase Openthe perimetersuction panel(Fig.
OPERATION 2 WHEN SHOULD THE HOOD BE SWITCHED ON AND OFF? Switch on the hood at least one minute before starting to cook: this enhances the airlow to convey fumes and vapours towards the suction surface. After cooking, leave the hood operating until complete extraction of all vapours and odours. If required, for versions with electronic push button control panel, by means of the Timer function, it is possible to set hood auto switch-of after 15 minutes of operation.
USE OF THE ELECTRONIC PUSH BUTTON CONTROL PANEL CLEANING OF INTERNAL PARTS If required, the hood can be manually controlled by using the keyboard on the hood structure. It is forbidden to clean electrical parts, or parts related to the motor inside the hood, with liquids or solvents. Do not use abrasive products. All these operations are to be carried out after having disconnected the equipment from the electrical mains power supply.