User's Manual

G-scan2 User Manual
118
E. Two Cursor A
Cursor A is a vertical red dot line, and the parameter values at the time of the cursor point
are indicated on the right side of the screen.
Also the elapsed time from the start point to the cursor position is indicated in the bottom
right corner.
F. Two Cursor B
Trigger B is activated and appears as the vertical green dot line as shown below.
The minimum and maximum values between the positions of Cursor A and B are indicated
in the right side of the screen.
Also the time difference between the cursor A and B is indicated in the bottom right corner.