Users Manual

Operating Instructions Smart Weather Sensor
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 115
Device configured for measurement in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Buffer ‘0’
Air Temperature (act)
105
-58.0
140.0
°F
Rel. Humidity (act)
200
0.0
100.0
%
Dew Point (act)
115
-58.0
14.0
°F
reserved
Rel. Air Pressure (act)
305
300.0
1200.0
hPa
Buffer ‘1’
Precipitation Type
700
0, 40
Precipitation Intensity
840
0.0000
7.8740
in/h
Amount of Precip. Difference
645
0.0000
3937.0000
in
Amount of Precip. Absolute
640
0.000
3937.000
in
Buffer ‘2’
Air Temperature (min)
125
-58.0
140.0
°F
Air Temperature (max)
145
-58.0
140.0
°F
Air Temperature (avg)
165
-58.0
140.0
°F
Rel. Humidity (min)
220
0.0
100.0
%
Rel. Humidity (max)
240
0.0
100.0
%
Buffer ‘3’
Rel. Humidity (avg)
260
0.0
100.0
%
Rel. Air Pressure(min)
325
300.0
1200.0
hPa
Rel. Rel. Humidity (max)
345
300.0
1200.0
hPa
Rel. Rel. Humidity (avg)
365
300.0
1200.0
hPa
Wet Bulb Temperature (act)
119
-58.0
140.0
°F
Specific Enthalpy
215
-100.0
1000.0
kJ/kg