Users Manual

Operating Manual Smart Weather Sensor
18 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
6.5 Wet Bulb Temperature
Sampling rate 1 minute
Units °C; °F
Request channels:
UMB Channel
Measuring Range
act
Measurement Variable (float32)
min
max
unit
114
Wet Bulb Temperature
-50.0
60.0
°C
119
Wet Bulb Temperature
-58.0
140.0
°F
6.6 Specific Enthalpy
Sampling rate 1 minute
Unit kJ/kg
Request channels:
UMB Channel
Measuring Range
act
Measurement Variable (float32)
min
max
unit
215
Specific Enthalpy
-100.0
1000.0
kJ/kg
6.7 Air Density
Sampling rate 1 minute
Unit kg/m³
Request channels:
UMB Channel
Measuring Range
act
Measurement Variable (float32)
min
max
unit
310
Air Density
0.0
3.0