Users Manual

Operating Manual Smart Weather Sensor
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 33
9 Commissioning
After the equipment has been installed and connected correctly, the sensor begins
autonomously to take measurements. A Windows
®
PC with serial interface, ConfigTool.NET
software and interface cable (SUB-D 9 pole; jack - socket; 1:1) are required for configuration
and test purposes.
Attention must be paid to the following points:
Check for correct equipment operation on site by carrying out a measurement request with
the aid of ConfigTool.NET (see page 44).
Configure the local altitude in order to ensure the correct calculation of relative air
pressure (see page 37).
The device must be aligned to the North in order to ensure correct wind measurement
(see page 27), or the automatic compass correction must be activated (see page 37).
In order to get correct compass headings the local declination must be configured (see
page 20and 37).
If several Smart Weather Sensors are operated on a UMB network, a unique device ID
must be assigned to each device (see page 36).
There is no protective cover to remove on the sensor itself.