Users Manual

Operating Manual Smart Weather Sensor
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 35
Figure 8: Select a
Workspace
Figure 9: Sensor
Selection
10.1 Factory Settings
The Smart Weather Sensor is delivered with the following settings:
Class ID: 7 (cannot be modified)
Device ID: 1 (gives address 7001h = 28673d)
Baud rate: 19200
RS485 protocol: Binary
Calculation interval: 10 measurements
Local altitude: 0 m
Note: The device ID must be changed if several Smart Weather Sensors are operated on a
UMB network, as each device requires a unique ID. It makes sense to start from ID 1 and
continue in ascending order.
10.2 Configuration with the UMB-Config-Tool
The operation of the UMB-ConfigTool.NET is described in detail in help function of the
Windows
®
PC software. For this reason only the menus and functions specific to the Smart
Weather Sensor are described here.
10.2.1 Sensor Selection
Select an existing workspace or create a new one.
Add a new device to the workspace by clicking the “+” button.
The Smart Weather Sensor is shown here as sensor selection WSx-UMB (Class ID 7).
Enter a name for the new device and adjust the device ID if necessary. Store the
modifications with “OK”.