Users Manual

Operating Manual Smart Weather Sensor
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 41
Figure 20: Select
operation mode
„Simulated Rain
Gauge“
Figure 21: Configure
the resolution of the
simulated rain gauge
Figure 22: WMO station
settings
10.2.13 (WS100-UMB only) Setting of Rain Gauge Simulation
Note: For configuration settings of the WS100-UMB do not use UMB-Config-Tool, but
ConfigTool.NET. For details of operation please refer to the software manual of
ConfigTool.NET.
Note: while the rain gauge simulation is active communication through the serial interface in
UMB or another serial protocol is not possible. To still allow access to the device for
modification of settings etc. UMB protocol will be active during the first 5 sec after power on.
The necessary procedure is described in detail in chapter 19.6.1.
Rain gauge simulation is selected as a protocol setting.
The resolution of the simulated rain gauge is defined in the field „Sim. RainGauge
Resolution. Factory setting is 0.01mm, alternatively 1.0mm, 0.5mm, 0.2mm or 0.1mm may
be selected.
10.2.14 WMO Station settings (WS100-UMB only)
In connection with the output of the WMO Synop Codes (see 6.15.1), detailed information on
the respective station can be stored in the device. These settings can be found in the "WMO"
configuration section.