Users Manual

Operating Manual Smart Weather Sensor
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 47
Figure 26: Operating
Modes for Equipment
Heating
10.5 Operating Modes for Equipment Heating
Heating is configured to ‘Automatic’ when the product is delivered. This is the recommended
operating mode for heating the sensor.
You can set the following operating modes:
Heater
Mode
WS100-
UMB
WS200-
UMB
WS400-
UMB
WS500-
UMB
WS501-
UMB *)
WS600-
UMB
**)
WS601-
UMB
Automatic
Off
Mode 1
Eco-Mode 1
*) is also valid for WS502-UMB, WS503-UMB, WS504-UMB, WS510-UMB
**) is also valid for WS700-UMB and WS800-UMB
Note: Model WS30x-UMB and WS401-UMB are not heated.
The rain sensor and wind meter settings must be adjusted in the respective configuration
mask. The examples show the wind meter setting.
10.5.1 Automatic
In this operating mode, the sensor is maintained constantly at the control temperature,
generally in order to prevent the effects of snow and ice.
Setpoint Temp.: The heating controls at this temperature (in °C)
Heating mode1 Temp.: Threshold temperature (in °C) with effect from
which air temperature heating is enabled
Eco mode1 follow-up time: Follow-up time (in minutes)
10.5.2 Off
In the ‘Off’ operating mode heating is completely disabled. Winter operation is not possible in
this operating mode because any icing might prevent the correct operation of the rain sensor
or wind meter.
10.5.3 Mode 1
In ‘Mode 1’ operating mode heating is only enabled when the outside temperature falls below
the HeatingMode1 temperature (in °C). In this mode power consumption can be reduced in
frost-free situations with no great restriction on winter operation.