Users Manual

Operating Instructions Smart Weather Sensor
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 89
E9<CR>* precipitation total particles Tt - (Channel 4600)
precipitation total drops Td - (Channel 4601)
precipitation drizzle particles Dr - (Channel 4602)
precipitation snow particles Sn - (Channel 4603)
precipitation hail particles Ha - (Channel 4604)
precipitation drop class 0 C0 - (Channel 4620)
precipitation drop class 1 C1 - (Channel 4621)
precipitation drop class 2 C2 - (Channel 4622)
precipitation drop class 3 C3 - (Channel 4623)
precipitation drop class 4 C4 - (Channel 4624)
precipitation drop class 5 C5 - (Channel 4625)
precipitation drop class 6 C6 - (Channel 4626)
precipitation drop class 7 C7 - (Channel 4627)
precipitation drop class 8 C8 - (Channel 4628)
precipitation drop class 9 C9 - (Channel 4629)
precipitation drop class 10 C10 - (Channel 4630)
precipitation drop class 11 C11 - (Channel 4631)
Mx<CR> Displays the same values as Ex<CR>, but without additional information such as the
measurement variable and unit
I0<CR> Serial number; date of manufacture; project number; parts list version;
SPLAN version; hardware version; firmware version; E2 version; device version
I1<CR> Outputs the device description
R0<CR> Executes a device reset
R1<CR> Resets the accumulated rain quantity and executes a device reset
X0<CR> Temporarily switches to UMB binary protocol
*) Command E9/M9 is only supported by WS100-UMB
Examples:
E0<CR> E0;Ta+024.9C;Tp+012.2C;Tw+026.8C;Hr+045.0P;Pa+0980.6H;
Sa+005.1M;Da+156.6D;Ra+00042.24M;Rt+060N;Ri+002.63M;
M0<CR> M0;+024.9;+012.2;+026.8;+045.0;+0980.6;
+005.1;+156.6;+00042.24;+060;+002.63;
E2<CR> E2;Sa+005.1M;Sn+001.1M;Sx+007.1M;Sg+005.1M;Sv+005.0M;
Da+156.6D;Dn+166.6D;Dx+176.6D;Dv+156.6D;
M2<CR> M2;+005.1;+001.1;+007.1;+005.1;+005.0;
+156.6;+166.6;+176.6;+156.6;
I0<CR> I0;001;0109;0701;004;005;001;016;011;00002;<CR><LF>
R0<CR> R0;OK;<CR><LF>