ELECTRICAL SPECIFICATIONS:
Frequency Range : UL CELL AB 824-849 MHz
: UL PCS 1850-1910 MHz
: DL CELL AB 869-894 MHz
: DL PCS 1930-1990 MHz
Pass Band Gain @ normal operation : 80 dB (Min.)
Variable Step Attenuator Range : 0-30 dB
(2-dB steps)
Pass band Ripple : ±1.5 dB (Typ.)
Noise Figure @+25ºC at max gain : 5.0 dB (Max.)
3rd Order Intercept point
Uplink : +46 dBm (Typ.)
Downlink : +46 dBm (Typ.)
Output Power @ 1dB Compression
Uplink : +34 dBm (Typ.)
Downlink : +34 dBm (Typ.)
Output Power ALC Set Point
Uplink : +27 dBm ±1 dB
Downlink : +27 dBm ±1 dB
Isolation between Up/Down Link : 100 dB (Min.)
Input/ Output Impedance : 50 Ohms
VSWR (Input/Output) : 1.5: 1 (Max.).
Power Supply : 110VAC/0.8 Amp
: 240VAC/0.4 Amp
: 50 to 60 Hz