User's Manual

ELECTRICAL SPECIFICATIONS:
Frequency Range : See Table
Pass Band Gain @ min attenuation : 90 dB (typ.)
Variable Step Attenuator Range : 0-30 dB
(2-dB steps)
Pass band Ripple : ±1.5 dB (typ)
Noise Figure @+25°C at max gain : 5.0 dB max.
3rd Order Intercept point
Uplink : +45 dBm (typ)
Downlink : +55 dBm (typ)
*Output Power @ 1dB Compression
Uplink : +33 dBm (typ)
Downlink : +44 dBm (typ)
*Maximum Output power per Carrier
Uplink Single Carrier : +25.0 dBm
Two Carriers : +20.25 dBm
Three Carriers : +18.25 dBm
Downlink Single Carrier : +37.0 dBm
Two Carriers : +33.25 dBm
Three Carriers : +30.25 dBm
Maximum Input power per Carrier @ Max Gain
Uplink Single Carrier : -55 dBm
Two Carriers : -60 dBm
Three Carriers : -62 dBm
Downlink Single Carrier : -43 dBm
Two Carriers : -47 dBm
Three Carriers : -50 dBm
Isolation between Up/Down Link : 105 dB min.
Input/ Output Impedance : 50 Ohms
VSWR (Input/Output) : 1.5: 1 max.
Power Supply : 110VAC/1.3 Amp
: 240VAC/0.60 Amp
: 50 to 60 Hz
*The Manufacturer's rated output power of this equipment is for single carrier operation. For situations
when multiple carrier signals are present, the rating would have to be reduced by minimum of 3.75
dB, especially where the output signal is re-radiated and can cause interference to adjacent band
users. This power reduction is to be by means of input power or gain reduction and not by an
attenuator at the output of the device. (See above table for multiple carrier signal output power
ratings)
Page 5