User's Manual

ELECTRICAL SPECIFICATIONS:
Frequency Range Uplink : 806-824 MHz
Downlink : 851-869 MHz
System Pass band Gain @ min attenuation
Downlink : 60 dB (Typ.)
Uplink : 60 dB (Typ.)
Variable Step Attenuator Range (2-dB steps)
Uplink : 0-30 dB
Downlink : 0-30 dB
Pass band Ripple : ±1.5 dB (Typ.)
Noise Figure @+25°C at max gain
Uplink : 5.0 dB (Max.)
3rd Order Intercept point
Downlink : +55 dBm (Typ.)
*Output Power @ 1dB Compression
Downlink : +44 dBm (Typ.)
*Output power per Carrier
Uplink Single Carrier : +5.0 dBm
Downlink Single Carrier : +36.0 dBm
Input/ Output Impedance : 50 Ohms
VSWR (Input/Output) : 1.5: 1 (Max.)
Power Supply : 110VAC/1.5 Amp
: 220VAC/0.75 Amp
: 50 to 60 Hz
*The Manufacturer's rated output power of this equipment is for single carrier operation. For situations
when multiple carrier signals are present, the rating would have to be reduced by minimum of 3.5 dB,
especially where the output signal is re-radiated and can cause interference to adjacent band users.
This power reduction is to be by means of input power or gain reduction and not by an attenuator at
the output of the device. (See above table for multiple carrier signal output power ratings)
Page 5