User Manual

7 | Page
15 Amp
15
Amp
12 Volt
Lead-
Acid
Battery
12 Volt
Lead-
Acid
Battery
+
+
+ Battery
of
-
Optional Battery Back-Up Configuration
Figure 2: Optional Battery Back-Up Configuration
OutputComposite
Power
Typical DC
Current
Draw
@24VDC
[A]
Battery
Back-Up Time
[Hours]
Recommend
Battery Rated
Capacity
(20 Hour Rate)
[Amp Hours]
37 dBm 3.55
4
17.75
8
35.5
12
53.25
24
106.5
33 dBm 2.47
4
12.35
8
24.7
12
37.05
24
74.1
31 dBm 2.35
4
11.75
8
23.5
12
35.25
24
70.5
27 dBm 2.1
4
10.5
8
21
12
31.5
24
63
Note: We do not guarantee specifications under Battery Back-Up power.