PID2_UserManual.doc 22
Chapter 6: PATROL SUITE RF Power Down
If the equipment is being removed from the participant, the necessary adjustments should first be made to
their record in the appropriate Monitoring System. For questions concerning the termination process,
please call the G4S Justice Services Monitoring Center at 1(800) 589 6003. After following the
administrative procedures above, you may decommission the participant’s equipment.
Power Down Options
There are three Power Down options to choose from. Please select the Power Down Option that is most
appropriate.
Option Description
Power Down: ALL
Powers down the enrolled PID as well as the PHMU (PID must be
in range)
Power Down: PHMU
PHMU powers down. Although PID is no longer monitored by the
PHMU, it is not powered down.
Power Down: PID
PHMU removes PID from monitoring with the option to power
down or just remove.
Power Down: ALL
1. Select OFF from the Setup Menu to access the
Power Down Menu.
2. Select ALL from the Power Down Menu.
a. If the PHMU has any Stored Events, select
SEND to report all events or select SKIP
to bypass and transmit at a later time.
3. Make sure the enrolled PID is within range and cut
the PID Band when the instruction displays. The
PID will emit a series of short descending LED
blinks to indicate that it has been powered down.
a. If the PID is not present or the band is not cut after one minute, the LCD Screen will time
out and offer the option to RETRY or SKIP to the next step.
4. Disconnect the power when the instruction
displays.
NOTE: Do not turn or remove the PHMU Menu
Key until the LCD turns off.