Sensor over limit (OL)
The sensor over limit (OL) notification is activated when your G6 detects
that the gas reading has exceeded the range of its sensor.
When you acknowledge the high urgency notification, G6’s Home screen
and banner will reflect the OL status until the OL event is resolved.
The device’s red light pattern will persist after you acknowledge/mute the
notification until the OL event is resolved.
If muted OL event conditions persist past 60 seconds, the OL notification
will retrigger with lights, sound, and vibration until the OL event is
resolved.
Following the OL gas notification, the logged peak value of the OL gas
event is displayed on the Gas options screen.
The screen will show the peak value recorded until a new peak is
reached, the peak value is manually reset, or the peak value automatically
resets.
For more information on viewing and resetting gas readings, refer to
Viewing and Resetting Gas Readings.
NOTE:
If connectivity is unavailable, event data is stored and uploaded to
Blackline Live during the next scheduled synchronization for your device.