User's Manual

Table Of Contents
©2022 Blackline Safety Corp G6 Technical User Manual | 44
Uncontrolled when printed Rev 01
NOTE:
Your device’s active language is flagged with a check
mark.
2. Using the navigation buttons, scroll through the Languages
options and select a new primary language for your device by
pressing the center button ( )
.
3. To return to the Device settings menu, scroll to
Back
and
select it by pressing the center button (
).
8.3 GAS INFO MENU
Use the Gas info menu to view your device’s gas settings, including:
O
2
Devices H
2
S, SO
2
, CO Devices
Gas sensor (O
2
)
High enrichment (%vol)
Low enrichment (%vol)
Baseline (%vol)
Low depletion (%vol)
High depletion (%vol)
Peak enrichment (%vol)
Peak depletion (%vol)
Last bump test (date)
Last calibration (date)
Calibration gas concentration (from your
device’s configuration profile) (%vol)
Gas sensor (H
2
S, SO
2
, or CO)
High setpoint (ppm)
Low setpoint (ppm)
Peak gas reading (ppm)
STEL calculation (ppm/15 min)
Last bump test (date)
Last calibration (date)
Calibration gas concentration (from your
device’s configuration profile) (ppm)
To view gas information:
1. Using the navigation buttons, scroll through the Device
settings menu and select
Gas info
by pressing the center
button (
).
The Gas info screen opens.