The firmware install process requires that the device be restarted to commit and run the new
version of firmware. Once completed, G6 will continue to monitor as usual.
WARNING: G6 will NOT monitor during the firmware update installation process and
updates should therefore only take place while your device is in a safe, gas free
environment.
10.2.1 AUTOMATIC FIRMWARE INSTALLATION
Automatic firmware installs take place exclusively when your G6 is docked and assumed to be
in gas free environment where maintenance based operations can be performed.
IMPORTANT: While docked, G6 has a continuous network connection. After a docked bump
test or calibration, G6 automatically verifies whether a new version of firmware has been
downloaded onto the device. If so, G6 initiates the firmware install process after the device is
removed from G6 Dock.
If the device needs to install a new version of firmware following the docked bump test or
calibration, your device will notify you that it will automatically restart in order to update the
device’s firmware. In addition, your G6 will notify you that the firmware has successfully
updated during your device’s start-up sequence.
10.2.2 MANUAL FIRMWARE INSTALLATION
You can manually verify and update your firmware using your device’s Device settings menu.
Use the manual update procedure when you are out of range of a G6 dock and need to install
a new firmware version immediately, or do not have a dock allowing for automatic firmware
installs.
NOTE: Manual installs are only available if a new version of firmware has been downloaded
onto your device, and the new version of firmware has not already been automatically
installed.
For more information on manually updating your device, refer to Update Device Menu
.