Instructions / Assembly
Quick Specs
HydroStop® PremiumCoat® Liquid-Applied Roong (LAR) – Version 1.3
38
QUICK SPEC
GYPSUM ROOF BOARD (Densdeck® & Securock®) –
HYDROSTOP® PREMIUMCOAT® (HS-10)
Method
Requirements
Applicaon
Instrucons
• Roof must be clean, dry, and tight.
• Adhesion test required to ensure proper adhesion to substrate(s).
• If mechanically attached, plates must be encapsulated with Butter Grade Flashing.
• Apply at 50°F (10°C) and rising with no rain, dew, fog or freezing temperatures in
forecast for 24 hours.
• GAF recommends that the surface temperature be at or less than 110°F (43°C)
during application.
1. Before applying the HydroStop® PremiumCoat® System, an adhesion test is
required to ensure an adhesion of a minimum of 2.0 PLI. Test patches to be
applied with system rates listed below.
2. Ensure roof is free of dirt, debris, oil, and other contaminants that could
negavely aect adhesion.
3. The gypsum roof board should be at least 1/2” thick. Refer to local building code
for further coverboard and insulation requirements.
4. In most cases, no primer is required for this substrate. (Note: Using a compable
pre-primed gypsum board can prevent addional coang from being soaked into
the board, and it is preferred.)
5. All seams must be treated with flashing grade and fabric.
6. Apply HydroStop® PremiumCoat® Foundaon Coat and Finish Coat per the chart
below.
NOTE: The following “Quick Spec” is an abbreviated specicaon and is not meant to replace the detailed
specicaon. Read the enre 3-Part CSI System Specicaon prior to starng the project. Specicaons are
available at www.gaf.com.
•
Use GAF Roof Brush to apply HydroStop® PremiumCoat® Foundaon Coat
•
Spray, roller, or brush apply HydroStop® PremiumCoat® Finish Coat
SEAMS & DETAILS | HYDROSTOP® PREMIUMCOAT® SYSTEM
Treatment Type Product
Total
(Gal/Sq)
DFT*
(mils)
3-Coursed Rates HydroStop® Buer Grade and Fabric 4.0 43
Flashing Grade Only Rates HydroStop® Buer Grade 2.0 19
GYPSUM (DENSDECK® & SECUROCK®)
HYDROSTOP® PREMIUMCOAT® SYSTEM
Foundaon Coat
(with fabric)
Finish Coat System Warranty
Total
(Gal/Sq)
DFT*
(mils)
1st Coat
(Gal/Sq)
2nd Coat
(Gal/Sq)
3rd Coat
(Gal/Sq)
Total
(Gal/Sq)
DFT*
(mils)
Total
(Gal/Sq)
DFT*
(mils)
Emerald
Pledge™
Diamond
Pledge™
10 Year 2.5 27 0.75 0.75 1.50 13 4.00 40 Yes Yes
15 Year 2.5 27 1.00 1.00 2.00 17 4.50 44 Yes Yes
20 Year 2.5 27 1.00 1.00 1.00 3.00 25 5.50 52 Yes Yes
* Dry Film Thickness (DFT) is rounded to nearest mil, and is theorecal. Actual DFT will vary dependent on substrate prole, applicaon
technique and waste factor.