Brochure

EnergyGuard
Polyiso
EnergyGuard
NH Polyiso
EnergyGuard
Ultra*
EnergyGuard
NH
Ultra*
EnergyGuard
Barrier
EnergyGuard
NH
Barrier
EnergyGuard
HD/HD PLUS
EnergyGuard
NH
HD/HD PLUS
Roof
Type
New
Re-cover
Retrofit (metal)
Attribute/Benefit
Highest R-value
Lightweight; easy to handle and cut
Contains no CFCs or HCFCs; has zero ODP
and is EPA compliant
Reinforced cellulosic felt facers
Coated glass fiber
(bottom)
(bottom)
Premium coated glass fiber
(top)
(top)
Flat board product in 4' x 4' (1.21 m x 1.21 m) or
4' x 8' (1.21 m x 2.44 m)
Tapered board product (4' x 4' [1.21 m x 1.21 m] only)
Roof Challenges
High-traffic roof
High-humidity structure
Resistance to mold (ASTM D3273)
Achieves an ANSI/UL 790 Class A roofing fire rating over
combustible decks with a 1" (25.4 mm) board thickness
Approved component of Class 1-SH (Hail)
Rated Assembly
Transparency
Red List Free product
HPD (Health Product Declaration)
EPD (Environmental Product Declaration)
PIMA Quality Mark
GreenCircle Certified – Recycled Content
Codes Compliance
C1289/Type II/Class 1/Grade 2 (20 psi)** and
Grade 3 (25 psi)
C1289/Type II/Class 2/Grade 2 (20 psi)** and
Grade 3 (25 psi)
C1289/Type 2/Class 4/Grade 1
C1289/Type 2/Class 4/Grade 2
FM (4450/4470)
UL (ANSI/UL 790, ANSI/UL 1256, ANSI/UL 263)
††
UL (ANSI/UL 790)
Miami-Dade County Product Control Approved
State of Florida Approved
ROOF INSULATION PRODUCTS
ROOF INSULATION PRODUCTS
Choosing the Right Polyiso Insulation
For Your Roofing System
Choosing the right polyiso for a roofing system can be confusing. There are many different types of
facers and attributes to meet the required energy codes and specifications. So which type of polyiso
meets the needs of the roofing system for your building?
* Class A roofing fire rating over combustible deck when used with single-ply TPO, a total of at least
3" (76 mm) of EnergyGuard
Ultra is required; a Class B fire rating is also obtained when using at
least a single layer of 1.5" (38.1 mm).
**Stated dimensional stability tolerance: board thickness shall not diminish by more than 2% max.
Refer to FM Approvals RoofNav online for actual assemblies.
††
Refer to UL Online Certication Directory for actual assemblies.
NOTE: With the exception of EnergyGuard
HD/HD PLUS Polyiso and EnergyGuard
NH HD/NH HD PLUS Polyiso, stated dimensional stability tolerance: board thickness shall not diminish by more
than 2% max. Some membrane systems may require a non-polyisocyanurate cover board, the use of GAFGLAS
®
Stratavent
®
Perforated Venting Base Sheet, or a mechanically attached base sheet over
polyisocyanurate insulations. Check the membrane specification for installation, code, and warranty requirements.
14 15